Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Biosci. j. (Online) ; 37: e37005, Jan.-Dec. 2021. ilus, tab
Article in English | LILACS | ID: biblio-1359867

ABSTRACT

This study aimed to analyze the shear bond strength (SBS) of ceramic orthodontic brackets bonded with two different adhesive systems to intact and eroded teeth. Ceramic brackets were bonded to 72 bovine central incisors divided into four groups, defined by two study factors: enamel condition (control group, kept in artificial saliva; and experimental group, eroded by using immersion cycles in Coke™ for 90 seconds, every six hours for five days), and adhesive system type (Transbond™ XT or Transbond™ Plus Color Change). Polycrystalline ceramic brackets were adhesively fixed on all specimens using the same light curing protocol. SBS was tested using 0.5 mm/min and the failure mode was classified. SBS data was analyzed using two-way ANOVA followed by Tukey test. The adhesive remnant index (ARI) scores were analyzed using Kruskal-Wallis test with Dunn's post-hoc pairwise comparison (α=0.05). Percentages of ARI scores between the groups were compared by Fisher's exact test. Spearman's correlation coefficient was applied to investigate the correlation between ARI scores and SBS values. Only the adhesive system factor had significant effect on SBS (p=0.014), Transbond™ Plus Color Change showing higher values. No significance was found for enamel condition (p=0.665) or the interaction between adhesive system and enamel condition (p=0.055). ARI scores frequencies differed between groups (p<0.001). The median ARI scores were statistically different for most comparisons among the groups. However, no significant correlation was found between ARI scores and SBS. In conclusion, the type of adhesive system affected the SBS of ceramic brackets to dental enamel, but the enamel condition, intact or eroded, had no significant effect. There was no correlation between ARI scores and SBS values, although eroded enamel tended to retain more adhesive after bracket removal.


Subject(s)
Tooth Erosion , Orthodontic Brackets , Dental Cements
2.
Braz. oral res. (Online) ; 35: e119, 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350375

ABSTRACT

Abstract: To evaluate the effect of selective or nonselective carious tissue removal and the use of a resin-modified glass ionomer (RMGIC) liner under bulk fill resin composite restoration on the stress at the pulp chamber, the elastic moduli of hard, firm, soft and intact dentin were calculated using nanoindentation. Post-gel shrinkage of the bulk fill resin composite and RMGIC were determined using the strain-gauge method. Six finite element models were created by using digital radiography with the combination of two study factors: a) carious tissue removal: selective removal or nonselective removal of carious tissue, and b) use of RMGIC liner: with or without 1.0 mm of RMGIC liner. The modified von Mises stresses (mvm) (MPa) were extracted on the nodes of the internal wall of the pulp ceiling chamber at 100 N occlusal loading. Data were analyzed descriptively and recorded quantitively. Both study factors influenced the stress distribution. The mvm stress during the restorative procedure was higher for nonselective carious tissue removal without RMGIC (25.9 MPa) and lower for selective carious tissue removal associated with RMGIC (13.5 MPa). The dentin elastic modulus increased from soft carious (3.6 ± 0.3 MPa) to firm carious (5.2 ± 1.0 MPa) to hard carious (10.9 ± 1.2 MPa) to intact dentin (22.7 ± 3.0 MPa). Molars with carious lesions showed high mvm stress at the pulp ceiling (89.6 MPa) and at fragilized coronal structure remaining. Selective carious tissue removal followed by restoration using a Vitrebond liner and Tetric N-Ceram Bulk fill reduced the stress at the pulp chamber ceiling.

3.
Braz. oral res. (Online) ; 35: e001, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132750

ABSTRACT

Abstract: Three-point bending test is the most common mechanical test used for quantifying the biomechanical quality of bone tissue and bone healing in small animals. However, there is a lack of standardization for evaluation of bone repair by cortical perforation. The aim of this study was to determine the influence of bone defect position in the proximal metaphysis of rat tibias during load application and different span configuration on the three-point bending test outcomes. Cortical defects with 1.6 mm diameter were created at a standardized location on the medial surface of 60 tibias of male Wistar rats. The animals were euthanized 7 days after surgery. Five specimens were used to create 3D models for finite element analysis using high-resolution micro-CT images. Two spans (6 and 10mm) and three positions of the bone defect in relation to the load application (upward, frontal and downward) were evaluated experimentally (n = 10) and in finite element analysis (n = 5). Maximum load (N) and stiffness (N/mm) were statistically analyzed with 2-way ANOVA and Tukey test (α = 0.05). The results demonstrated that span and orientation of the bone defect significantly influenced the fracture pattern, stress distribution and force versus displacement relation. Therefore, reliable outcome can be achieved creating the bone defect at 8 mm from the extremity of the proximal epiphysis; placing a 10 mm distance span and downward facing defect position to allow a better distribution of stress and more fracture patterns that reached the bone defect target area with less intra-group variability.


Subject(s)
Animals , Male , Rats , Tibia , Mechanical Phenomena , Bone and Bones , Rats, Wistar , Finite Element Analysis
4.
Braz. oral res. (Online) ; 31(supl.1): e62, Aug. 2017. graf
Article in English | LILACS | ID: biblio-889457

ABSTRACT

Abstract Polymerization shrinkage stress of resin-based materials have been related to several unwanted clinical consequences, such as enamel crack propagation, cusp deflection, marginal and internal gaps, and decreased bond strength. Despite the absence of strong evidence relating polymerization shrinkage to secondary caries or fracture of posterior teeth, shrinkage stress has been associated with post-operative sensitivity and marginal stain. The latter is often erroneously used as a criterion for replacement of composite restorations. Therefore, an indirect correlation can emerge between shrinkage stress and the longevity of composite restorations or resin-bonded ceramic restorations. The relationship between shrinkage and stress can be best studied in laboratory experiments and a combination of various methodologies. The objective of this review article is to discuss the concept and consequences of polymerization shrinkage and shrinkage stress of composite resins and resin cements. Literature relating to polymerization shrinkage and shrinkage stress generation, research methodologies, and contributing factors are selected and reviewed. Clinical techniques that could reduce shrinkage stress and new developments on low-shrink dental materials are also discussed.


Subject(s)
Composite Resins/chemistry , Dental Stress Analysis/methods , Polymerization , Resin Cements/chemistry , Curing Lights, Dental , Dental Stress Analysis/instrumentation , Materials Testing
5.
Braz. dent. j ; 28(1): 9-15, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839109

ABSTRACT

Abstract The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.


Resumo A alta irradiância e diferentes espectros de luz emitidos por aparelhos fotopolimerizadores (Fp) podem causar danos oculares. Este estudo avaliou a capacidade de 15 filtros de proteção ocular em bloquear a luz prejudicial de um Fp convencional (HP-3M ESPE) e outro de largo espectro (Valo, Ultradent). Utilizando sensor anterior do equioamento MARC-Patient Simulator (BlueLight Analytics inc.) a irradiância que passou através dos diferentes filtros protetores foi mensuradas três vezes. Os valores médios da irradiância que passaram pelos filtros foram analisados usando Análise de variância fatorial e pelo teste de Tukey (a= 0.05). O espetro emitido dos Fps através dos filtros também foi obtido. A análise de variância mostrou que a interação entre os filtros protetores e Fps influenciou significantemente a quantidade de luz transmitida (p<0,001). O teste de Tukey mostrou que a quantidade que luz transmitida através dos protetores oculares quando usado o HP-3M ESPE foi significantemente maior quando comparado aos valores para o Valo, independentemente do filtro testado. Quando foi utilizado a fonte de luz HP-3M ESPE, o filtro de proteção ocular permitiu significativamente maior passagem de luz, seguido por XL 3000, ORTUS, Google Professional, e pelo filtro Gnatus. O filtro do Valo foi o mais eficiente ao bloquear a luz prejudicial. Alguns filtros foram menos eficazes ao bloquear menores comprimentos de onde (<420 nm). No entanto, mesmo no pior cenário dos resultados deste estudo, os filtros foram capazes de bloquear ao menos 97% da irradiância emitida pelas fontes de luz testadas.


Subject(s)
Humans , Curing Lights, Dental/adverse effects , Eye Protective Devices/standards , Analysis of Variance , Optics and Photonics
SELECTION OF CITATIONS
SEARCH DETAIL